본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

갑상선수술 중 신경모니터링의 흔한 실패 이유와 그 해결

이용수  0

영문명
The various causes of intraoperative neuromonitoring failure and solutions
발행기관
대한신경모니터링학회
저자명
채영준(Young Jun Chai)
간행물 정보
『Journal of Neuromonitoring & Neurophysiology』Vol.5 No.1, 15~19쪽, 전체 5쪽
주제분류
의약학 > 일반외과학
파일형태
PDF
발행일자
2025.05.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

Thyroid surgery is associated with potential complications, particularly involving the recurrent laryngeal nerve and external branch of the superior laryngeal nerve, which significantly impact patient quality of life. Intraoperative neuromonitoring (IONM) has become a critical tool for preserving nerve function during surgery by providing real- time electromyographic (EMG) feedback. However, the reliability of IONM can be compromised due to various failures during nerve stimulation or EMG signal recording. This study explores the causes of IONM failure and proposes practical solutions to enhance its efficacy. Failures in nerve stimulation are often attributed to device errors, improper settings, or environmental factors such as wet surgical fields. Specific challenges in robotic or endoscopic surgeries, including electrical shunting and cable damage, are also discussed. Additionally, residual neuromuscular blockade from anesthesia can impede nerve response, which may be addressed by adjusting drug protocols or using reversal agents. EMG signal recording failures frequently result from improper positioning of EMG endotracheal tubes. Tube displacement, rotation, or insufficient depth leads to signal loss or false readings. Alternative methods, such as thyroid cartilage needle electrodes, are suggested for improved stability and signal quality. This study emphasizes the importance of a standardized protocol to mitigate IONM failures and enhance the accuracy of nerve monitoring during thyroid surgery. By addressing technical, procedural, and anatomical challenges, the findings contribute to reducing nerve injury, improving surgical outcomes, and ensuring better patient safety and quality of life.

영문 초록

목차

서론
본론
결론
Funding
Conflict of Interest
Data Availavility
Author Contributions
ORCID
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

채영준(Young Jun Chai). (2025).갑상선수술 중 신경모니터링의 흔한 실패 이유와 그 해결. Journal of Neuromonitoring & Neurophysiology, 5 (1), 15-19

MLA

채영준(Young Jun Chai). "갑상선수술 중 신경모니터링의 흔한 실패 이유와 그 해결." Journal of Neuromonitoring & Neurophysiology, 5.1(2025): 15-19

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제