- 영문명
- Evaluating the Usability of Medical Body Wrap in Whole Body Bone Scan
- 발행기관
- 대한핵의학기술학회
- 저자명
- 심동오(Dong-Oh Shim) 정우영(Woo-Young Jung) 류재광(Jae-Kwang Ryu) 박철홍(Cheol-Hong Park) 김윤재(Yoon-Jae Kim)
- 간행물 정보
- 『핵의학기술』Vol.28 No.1, 49~56쪽, 전체 8쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2024.05.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: When performing nuclear medicine examinations, body wraps or plastic supports are used to support and immobilize the patient's upper extremities to prevent patient safety accidents. However, the existing plastic supports compromised patient and staff safety, including finger entrapment and falls. Moreover, the body wrap provided by manufacturers compromised image quality such as upper extremities cutoff during whole body bone scan. Therefore, a new design of body wrap was developed to improve the issue, and this study aims to evaluate the usability of this medical body wrap.
Materials and Methods: To evaluate the usability of the newly designed medical body wrap, a quality assessment of whole body bone scan images and a user satisfaction survey were conducted. Adult patients (male:female=129:152, age: 60.3±12.4 years, BMI: 24.0±4.2) aged 16 years or older who underwent a whole body bone scan during two periods: June to July 2022 (before improvement, n=139) and June to July 2023 (after improvement, n=142) were randomly selected for image quality evaluation. Five radiotechnologists visually evaluated the posterior view of the whole body bone image, including the left and right elbow (2 points), arm (2 points), whether the hand is extended (2 points), whether the hand is included (2 points), and the number of visible fingers (10 points), with a total of 18 points, which were converted to 100 points and analyzed for difference before and after improvement using an independent sample t-test. The user satisfaction questionnaire was evaluated using a 5-point Likert scale among 16 radiotechnologists from three general hospitals who experienced the new body wrap.
Results: The image quality assessment was 82.0±13.8 before the improvement and 89.3±10.1 after the improvement, an average of 7.3 points higher, with a statistically significant difference (t=5.02, p<0.01). The user satisfaction survey showed an overall satisfaction rating of 4.1±0.8 for ease of use, 3.8±0.7 for scan preparation time, 3.9±0.7 for patient safety, 3.8±1.2 for scan accuracy, and 4.2±0.7 for recommendation (87.5% questionnaire response rate).
Conclusion: The developed body wrap showed higher image quality and user satisfaction compared to the old method. Considering these results, it is deemed that the new body wrap may be more useful than existing methods.
목차
서론
대상 및 방법
결과
고찰
결론
REFERENCES
해당간행물 수록 논문
- Incidentally detected abnormal finding of femoral bone mineral densitometry due to paraffin injections for buttock augmentation
- 전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가
- 핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰
- 뇌종양진단에 있어 18F-FET Brain PET/CT의 유용성에 대한 고찰
- SiPM PET/CT에서 3D 프린팅 기반 자체제작한 팬텀을 이용한 iMAR 알고리즘 유용성 평가에 관한 연구
- CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구
- 팬텀을 활용한 PET/CT 장비 별 영상 비교 평가
- Satisfaction survey on music listening in patient waiting areas and hallways
- The Effect of Contrast Agent on the Change of Hepatic Uptake of 99mTc-Mebrofenin in Patients with Liver Transplantation
- Synthetic Approach to 99mTc-labeled SPECT Radiotracers with Multi-nitroimidazoles for Hypoxia
- Incidentally detected abnormal finding of femoral bone density image due to treatment of postoperative lymphatic leakage
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선사 맞춤형 조영제 정맥주사 교육과정 개발
의약학 > 방사선과학분야 NEW
- 소아 복부 CT의 신체 크기 특이적 선량 추정치 평가
- 대한CT영상기술학회지 제27권 제2호 목차
- 소아 CT 데이터의 효과적인 잡음 제거: 성인 CT 데이터 기반 미세조정 기법의 적용
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!