- 영문명
- A study on the strategies to lower technologist occupational exposure according to the performance form in PET scan procedure
- 발행기관
- 대한핵의학기술학회
- 저자명
- 고현수(Hyun Soo Ko) 김호성(Ho Sung Kim) 남궁창경(Chang Kyeoung Nam-Kung) 윤순상(Soon Sang Yoon) 송재혁(Jae Hyuk Song) 류재광(Jae Kwang Ryu) 정우영(Woo Young Jung) 장정찬(Jung Chan Chang)
- 간행물 정보
- 『핵의학기술』Vol.19 No.1, 17~29쪽, 전체 13쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2015.05.30
4,360원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose For nuclear medicine technologists, it is difficult to stay away from or to separate from radiation sources comparing with workers who are using radiation generating devices. Nuclear medicine technologists work is recognized as an optimized way when they are familiar with work practices. The aims of this study are to measure radiation exposure of technologists working in PET and to evaluate the occupational radiation dose after implementation of strategies to lower exposure. Materials and Methods We divided into four working types by QC for PET, injection, scan and etc. in PET scan procedure. In QC of PET, we compared the radiation exposure controlling next to ⁶⁸Ge cylinder phantom directly to controlling the table in console room remotely. In injection, we compared the radiation exposure guiding patient in waiting room before injection to after injection. In scan procedure of PET, we compared the radiation exposure moving the table using the control button located next to the patient to moving the table using the control button located in the far distance. PERSONAL ELECTRONIC DOSEMETER (PED), Tracerco™ was used for measuring exposed radiation doses. Results The average doses of exposed radiation were 0.27±0.04 μSv when controlling the table directly and 0.13±0.14 μSv when controlling the table remotely while performing QC. The average doses of exposed radiation were 0.97±0.36 μSv when guiding patient after injection and 0.62±0.17 μSv when guiding patient before injection. The average doses of exposed radiation were 1.33±0.54 μSv when using the control button located next to the patient and 0.94±0.50 μSv when using the control button located in far distance while acquiring image. As a result, there were statistically significant differences(P<0.05). Conclusion: From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine. Conclusion From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine.
목차
서론
실험 대상 및 방법
결과
고찰
결론
요약
REFERENCE
해당간행물 수록 논문
- PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석
- 심장기능상태의 분류에 따른 게이트심장혈액풀 검사와 심장초음파의 심박출계수 상관관계에 관한 고찰
- ⁹⁹ᵐTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰
- 전신 뼈검사에서의 영상 평가 연구
- 18F-FDG Brain PET/CT 검사를 위한 데이터 비교 방법의 평가
- Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가
- 주성분분석을 이용한 C[11]-PIB imaging 영상분석
- DIACON 정도관리물질의 평가
- 혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교
- Dynamic study를 이용한 선조체에서의 ¹⁸F-DOPA의 분포에 대한 평가
- PET 검사실 종사자의 업무 행위 별 방사선피폭 조사에 따른 피폭선량 저감화를 위한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 호주 방사선 의료 전문가 면허제도 및 교육과정 고찰: 진단방사선사를 중심으로
의약학 > 방사선과학분야 NEW
- 소아 복부 CT의 신체 크기 특이적 선량 추정치 평가
- 대한CT영상기술학회지 제27권 제2호 목차
- 소아 CT 데이터의 효과적인 잡음 제거: 성인 CT 데이터 기반 미세조정 기법의 적용
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
