학술논문
子宮頸部癌 腔內 放射線 照射裝置에 依한 直腸 및 膀胱의 被曝線量 評價
이용수 23
- 영문명
- Dose Distribution of Rectum and Bladder in Intracavitary Irradiation
- 발행기관
- 대한방사선종양학회
- 저자명
- 추성실(S.S.Chu) 오원용(W.Y.Oh) 서창옥(C.O.Suh) 김귀언(G.E.Kim)
- 간행물 정보
- 『대한방사선종양학회지』제2권 제2호, 261~270쪽, 전체 10쪽
- 주제분류
- 의약학 > 종양학
- 파일형태
- 발행일자
- 1984.12.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy.
The complications of pelvic organ are known to be directly related to radiation dose and physical parameters.
The simulation radiogram and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct 1983, were critically analized.
The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system.
The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer.
Followings were summary of study results;
1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as 4~7 cm width and high dose rate system showed as 5~6 cm.
2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position 64.6%, left deviation 19/2% and right deviation 16.2%.
3. In longitudinal angulation of tandem to body axis, the mid position was 11.8% and anterior angulation 88.2% in low dose rate system but in high dose rate system, anterior angulation was 98.5%.
4. Down ward displacement of ovoids below external os was only 3% in low dose rate system and 66.7% in high dose rate system.
5. Inradiation source arrangement, the most activites of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system.
6. In low and high dose rate system, the total doses and TDF were 80, 70 Gy and 141, 123, including 40 Gy external irradiation.
7. The doses and TDF in interesting points Co, B, sere 98, 47 Gy and 230, 73 in high dose rate system but in low dose rate system, 125, 52 Gy and 262, 75 respectively.
8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy and 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, 30% and 18, 23% respectively.
목차
키워드
해당간행물 수록 논문
- 두경부 선낭암의 생물학적 특성과 치료
- 子宮頸部癌 腔內 放射線 照射裝置에 依한 直腸 및 膀胱의 被曝線量 評價
- 비소세포 폐암의 방사선 치료
- 성상세포종의 방사선치료성적
- 60Co γ선과 10MV X 선의 조사면 밖의 선량분포에 관한 연구
- 聲門上部癌 放射線治療 15年 成績
- 直腸癌의 手術後 放射線治療 成績
- 백서에서 발생시킨 유방암의 방사선 치료시 온열요법이 미치는 영향에 관한 실험적 연구
- 치료계획용 컴퓨터를 이용한 부정형조사면의 선량분포에 관한 실험
- 상부식도암의 방사선치료 방법
- External Beam Radiation Therapy of Adenocarcinoma of the Prostate
- 小細胞未分化肺癌의 放射線治療
- 국소재발 직장암의 방사선 치료
- 非小細胞性肺癌의 放射線治療 成績
- 腦腫瘍의 放射線治療後 發生한 慢性變化의 CT所見
- 6MV 선형가속기를 사용한 유방암 치료
- 백서에서 발생시킨 유방암의 방사선 치료시 온열요법이 미치는 영향에 관한 실험적 연구
- Treatment of Endometrial Carcinoma Stage II
참고문헌
관련논문
의약학 > 종양학분야 BEST
- Impact of adaptive radiotherapy on survival in locally advanced nasopharyngeal carcinoma treated with concurrent chemoradiotherapy
- 무릎관절의 미만형 색소 융모 결절성 활액막염에서 관절경을 이용한 육안적 활액막 전 절제술 후 방사선치료
- Application of surface-guided radiation therapy in prostate cancer: comparative analysis of differences with skin marking-guided patient setup
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!