본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

子宮頸部癌 腔內 放射線 照射裝置에 依한 直腸 및 膀胱의 被曝線量 評價

이용수  23

영문명
Dose Distribution of Rectum and Bladder in Intracavitary Irradiation
발행기관
대한방사선종양학회
저자명
추성실(S.S.Chu) 오원용(W.Y.Oh) 서창옥(C.O.Suh) 김귀언(G.E.Kim)
간행물 정보
『대한방사선종양학회지』제2권 제2호, 261~270쪽, 전체 10쪽
주제분류
의약학 > 종양학
파일형태
PDF
발행일자
1984.12.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The simulation radiogram and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct 1983, were critically analized. The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system. The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer. Followings were summary of study results; 1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as 4~7 cm width and high dose rate system showed as 5~6 cm. 2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position 64.6%, left deviation 19/2% and right deviation 16.2%. 3. In longitudinal angulation of tandem to body axis, the mid position was 11.8% and anterior angulation 88.2% in low dose rate system but in high dose rate system, anterior angulation was 98.5%. 4. Down ward displacement of ovoids below external os was only 3% in low dose rate system and 66.7% in high dose rate system. 5. Inradiation source arrangement, the most activites of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system. 6. In low and high dose rate system, the total doses and TDF were 80, 70 Gy and 141, 123, including 40 Gy external irradiation. 7. The doses and TDF in interesting points Co, B, sere 98, 47 Gy and 230, 73 in high dose rate system but in low dose rate system, 125, 52 Gy and 262, 75 respectively. 8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy and 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, 30% and 18, 23% respectively.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

추성실(S.S.Chu),오원용(W.Y.Oh),서창옥(C.O.Suh),김귀언(G.E.Kim). (1984).子宮頸部癌 腔內 放射線 照射裝置에 依한 直腸 및 膀胱의 被曝線量 評價. 대한방사선종양학회지, 2 (2), 261-270

MLA

추성실(S.S.Chu),오원용(W.Y.Oh),서창옥(C.O.Suh),김귀언(G.E.Kim). "子宮頸部癌 腔內 放射線 照射裝置에 依한 直腸 및 膀胱의 被曝線量 評價." 대한방사선종양학회지, 2.2(1984): 261-270

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제