Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement
이용수 12
- 영문명
- Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement
- 발행기관
- 대한방사선과학회(구 대한방사선기술학회)
- 저자명
- Tae-Hyung Kim(김태형) Gi-Young Ko(고기영) Ho-Young Song(송호영) In Kook Park(박인국) Ji Hoon Shin(신지훈) Jin-Oh Lim(임진오) Jin Hyoung Kim(김진형) Eugene K. Choi
- 간행물 정보
- 『방사선기술과학』방사선기술과학 제30권 제3호, 205~212쪽, 전체 8쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2007.09.01
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n=5, Wilcoxon"s signed ranks test).
The changes in blood pressures according to pulse rate were all statistically significant(p <0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were 157.80±1.92/130.20±1.92, 159.40±1.14/134.00±2.92, and 147.20±1.480/129.60±2.70mmHg, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to 161.40±1.34/90.20±1.64, 175.00±1.58/93.00±1.58, and 176.80±1.48/90.80±1.92mmHg, respectively, when the pulse rate was 1.0 beat/second, and 159.40±1.82/127.20±1.48, 166.60±1.67/138.00±1.87, and 161.00±1.22/135.40±1.67 mmHg, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were 143.60±1.67/90.20±1.64, 147.20±1.92/84.60±1.82, and 137.40±1.52/88.80±1.64mmHg after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p <0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p = 0.157).
The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.
목차
Ⅰ. INTRODUCTION
Ⅱ. MATERIALS AND METHODS
Ⅲ. RESULTS
Ⅳ. DISCUSSION
ACKNOWLEDGMENTS
Reference
국문초록
키워드
해당간행물 수록 논문
- 뇌경색 환자의 3Tesla CE-TOF-MRA에서 MT 펄스의 유용성
- Extravasation Injury of Contrast Media in the Neck and Thorax During MDCT Scanning with 3D Image Reformation Findings
- Paraffin을 이용한 Thyroid Phantom제작에 따른 유용성에 관한 연구
- 표지시간 변화에 의한 <SUP>99m</SUP>Tc과 적혈구 표지효율
- 중재적 방사선 분야 방호용구 차폐효과
- 대한방사선과학회 정관 외
- 초음파 검사자의 근골격계 증상에 영향을 주는 요인
- Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement
- 문제중심학습 모형을 적용한 방사선(학)과 교수학습 방안
- X선 및 감마선에 대한 apron의 차폐율 측정
- 디지털 의료영상에서 Edge method에 의한 Modulation Transfer Function 보정방법과 특이성
- 초음파검사에서 여성 골반내 질환별 발생빈도 조사연구
- 방사선과 학생의 직업가치관 유형에 관한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선사 맞춤형 조영제 정맥주사 교육과정 개발
의약학 > 방사선과학분야 NEW
- 재구성 알고리즘과 Butterworth 필터 차단 주파수가 핵의학 영상 화질에 미치는 영향: Prominence Processor 기반 시뮬레이션 연구
- 합성곱 블록 주의 모듈과 U-Net을 활용한 CT 영상 노이즈 제거 기법
- 요오드 조영제 자동 주입 시 외부 가온기 사용이 온도 변화에 미치는 영향
최근 이용한 논문
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!